Standard Forms and Drawings
Appendix B – Standard Forms
| Standard Forms | Revision Date | New |
|---|---|---|
| Construction Completion Certificate |
2007 - 04 | |
| Daily Inspection Report |
2007 - 04 | |
| Declaration of Engineer-Client Agreement |
2007 - 04 | |
| New Hydrant Installation Form |
2007 - 04 | |
| Standard Right-of-Way - Part 1 |
2007 - 04 | |
| Standard Right-of-Way - Part 2 |
2007 - 04 | |
| Statutory Declaration - Waterworks |
2007 - 04 | |
| Valve Data Form (PDF |
2007 - 04 | |
| Waterworks Extension Agreement |
2007 - 04 |
Appendix C – Standard Drawings
| Standard Drawing No. | Description | DWF | Revision Date | New | |
|---|---|---|---|---|---|
| General Waterworks | |||||
| 1.1 | Standard Air Valve Installation for > 300 mm Pipe | Download (PDF |
Download DWF | 2007-04 | |
| 1.2 | Air Valves – Typical Installation 100 – 300 mm pipe | Download (PDF |
Download DWF | 2007-04 | |
| 1.3 | Standard Fire Hydrant Assembly | Download (PDF |
Download DWF | 2007-04 | |
| 1.4 | Flush Assembly for > 300 mm Pipe | Download (PDF |
Download DWF | 2007-04 | |
| 1.5 | 50 mm and Low Point Flush Valve Installation | Download (PDF |
Download DWF | 2007-04 | |
| 1.6 | 100 mm Flush Assembly for Distribution Mains | Download (PDF |
Download DWF | 2007-04 | |
| 1.7 | Standard Line Valve Installation | Download (PDF |
Download DWF | 2007-04 | |
| 1.8 | Concrete Thrust Block Details | Download (PDF |
Download DWF | 2007-04 | |
| 1.9 | Mechanical Thrust Restraint Applications | Download (PDF |
Download DWF | 2007-04 | |
| 1.10 | Thrust Restraint Length | Download (PDF |
Download DWF | 2007-04 | |
| 1.11 | Thrust Restraint for Flexible Couplings | Download (PDF |
Download DWF | 2007-04 | |
| 1.12 | Standard Trench Detail | Download (PDF |
Download DWF | 2009-07 | new |
| 1.13 | Standard Water Valve Box | Download (PDF |
Download DWF | 2007-04 | |
| 1.14 | Hydrant Installation in Ditched Areas | Download (PDF |
Download DWF | 2007-04 | |
| 1.15 | Sewer Crossing under AC Water Main | Download (PDF |
Download DWF | 2009-07 | new |
| Services and Small Fittings | |||||
| 2.1 | 19 mm Reduced Pressure Backflow Preventer Above Ground | Download (PDF |
Download DWF | 2007-04 | |
| 2.2 | Double Check Backflow Preventer (50 mm & less) | Download (PDF |
Download DWF | 2007-04 | |
| 2.3 | Cast Iron Cover for 19 mm Meter | Download (PDF |
Download DWF | 2007-04 | |
| 2.4 | Existing Service Replacement | Download (PDF |
Download DWF | 2007-04 | |
| 2.5 | Water Service / Meter – Typical Layout for Multi-Family Dwellings | Download (PDF |
Download DWF | 2009-07 | new |
| 2.6 | Standard Water Service Connection | Download (PDF |
Download DWF | 2007-04 | |
| Valves Structural Details | |||||
| 3.1 | Precast 100 mm Sensus Fireline Meter Vault | Download (PDF |
Download DWF | 2007-04 | |
| 3.2 | Precast 150 mm Sensus Fireline Meter Vault | Download (PDF |
Download DWF | 2007-04 | |
| 3.3 | Precast 200 mm Sensus Fireline Meter Vault | Download (PDF |
Download DWF | 2007-04 | |
| 3.4 | Typical Double Check Valve Assembly Chamber - 100 mm & Larger | Download (PDF |
Download DWF | 2007-04 | |
| 3.5 | Standard Access Hatch | Download (PDF |
Download DWF | 2007-04 | |
| 3.6 | Standard Security Hatch | Download (PDF |
Download DWF | 2007-04 | |
| 3.7 | Interior Lifting Ring – Cast in Place | Download (PDF |
Download DWF | 2007-04 | |
| 3.8 | Lifting Hook – Channel Insert Detail | Download (PDF |
Download DWF | 2007-04 | |
| 3.9 | Sump Pump – Standard Installation | Download (PDF |
Download DWF | 2007-04 | |
| 3.10 | Automatic Sump Drain Assembly | Download (PDF |
Download DWF | 2009-07 | new |
| 3.11 | Thrust Plate and Seal Ring Detail | Download (PDF |
Download DWF | 2007-04 | |
| 3.12 | Precast 150 mm Pressure Control Station` | Download (PDF |
Download DWF | 2007-04 | |
| 3.13 | Water Meter Detail - Mechanical Room | Download (PDF |
Download DWF | 2009-07 | new |
| Miscellaneous | |||||
| 4.1 | Chlorine Injection Port for Reservoirs | Download (PDF |
Download DWF | 2007-04 | |
| 4.2 | Typical Drain Clean-out | Download (PDF |
Download DWF | 2007-04 | |
| 4.3 | Duplex Pilot Strainer Assembly | Download (PDF |
Download DWF | 2007-04 | |
| 4.4 | Grading Curve - 25mm Minus Crushed Road Base | Download (PDF |
Download DWF | 2007-04 | |
| 4.5 | Grading Curve - 75mm Minus Crushed Road Base | Download (PDF |
Download DWF | 2007-04 | |
| 4.6 | Grading Curve - Sand Bedding | Download (PDF |
Download DWF | 2007-04 | |
| 4.7 | Ladder Extension – Details | Download (PDF |
Download DWF | 2007-04 | |
| 4.8 | Water Sampling Point Enclosure Details | Download (PDF |
Download DWF | 2007-04 | |
| 4.9 | Water Sampling Port – Typical Detail for Concrete Reservoirs | Download (PDF |
Download DWF | 2007-04 | |
| 4.10 | Trench Dams for Slopes greater than 30% | Download (PDF |
Download DWF | 2007-04 | |
| 4.11 | Trench Dams for Slopes to 30% | Download (PDF |
Download DWF | 2007-04 | |
| 4.12 | Roof Vent and Enclosure for Reservoirs | Download (PDF |
Download DWF | 2007-04 | |
| 4.13 | Non-Potable Water Warning Sign | Download (PDF |
Download DWF | 2007-04 | |
| 4.14 | Water Sampling Point In-Ground Installation | Download (PDF |
Download DWF | 2009-07 | new |